| Product CodeFS0251 |
Safety Locker Sign – IMO marine safety sign.
Other sizes on request. Film specifications on the Specifications tab.
$12.65 – $59.40Price range: $12.65 through $59.40 inc GST
| Product CodeFS0251 |
Safety Locker Sign – IMO marine safety sign.
Other sizes on request. Film specifications on the Specifications tab.
| Product | |
| Product code | FS0251 |
|---|---|
| Sizes | 150 × 150 mm, 300 × 300 mm · other sizes on request |
| Film options | |
| Self-Adhesive Vinyl (Non-Glow) | Polymeric PVC with UV laminate. No glow. Up to 5 yrs outdoor. |
| General Purpose Glow Vinyl | 200 µm photoluminescent vinyl, approx. 8 hr afterglow. Not certified – not for marine or escape-route use. Up to 7 yrs outdoor. |
| Marine Glow Vinyl (Class C) | DNV MED Wheelmark, ISO 15370:2021. ≥140 / ≥20 mcd/m² at 10 / 60 min, 28+ hr afterglow. Flame-retardant. Up to 5 yrs outdoor. |
| Marine High Intensity Glow Vinyl (Class D) | DNV MED Wheelmark, ISO 15370:2021. ≥260 / ≥35 mcd/m² at 10 / 60 min, 50+ hr afterglow. Nearly 2× Class C – escape routes, LLL, low-light areas. Flame-retardant. Up to 5 yrs outdoor. |
| Substrates | |
| Self-adhesive | Peel-and-stick onto flat, clean, non-porous surfaces – bulkheads, doors, cabinets, painted steel. Default. |
| Rigid PVC | Light, economical panel for interior mounting. Screw or adhesive fix. |
| Polycarbonate | Impact-resistant, UV-stable – exterior and high-traffic locations. |
| Aluminium | Corrosion-resistant, long-life exterior and deck use. |
| Steel | Heavy-duty industrial mounting; magnet-compatible. |
Full film data sheets, certificates and care instructions on our Materials page.
This Safety Locker sign identifies the location of the vessel’s dedicated storage locker for firefighting outfits, breathing apparatus and associated safety equipment, shown by the standardised “SL” pictogram, matching exactly what appears on the vessel’s fire control plan for this location. As SKU FS0251 in the Fire Fighting Signs range, it is designed for permanent fixing at the locker or cabinet housing fireman’s outfits, SCBA sets and personal protective equipment for emergency response teams.
The safety locker holds the personal protective equipment fire teams depend on to enter smoke-logged or hazardous spaces safely, which makes fast, unambiguous identification important during both routine equipment checks and a genuine emergency muster. Clear signage also supports routine fire equipment rounds, where crew confirm outfits, breathing sets and accessories are complete, correctly stowed and ready for immediate donning. The photoluminescent background of this sign keeps the locker identifiable during a blackout, exactly when suiting up for a real incident becomes part of the crew’s firefighting response.
Crew responsible for fire team readiness need to locate the safety locker quickly for scheduled inventory checks, equipment servicing and drills, since incomplete or misplaced protective equipment can delay a fire team’s entry into an affected space. Correctly signed lockers also support fire drills and crew induction, helping new crew understand exactly where their protective equipment is stored before they are ever relying on it under pressure. This distinction matters particularly on vessels with more than one safety locker serving different zones, where confirming the correct locker for a muster station supports confident, fast response.
This sign reproduces the fire control symbol set derived from IMO Resolution A.654(16) and continued under the current ISO 17631 standard for fire control plan graphics, matching what flag-state surveyors and classification societies expect to see identifying safety equipment lockers. SOLAS Chapter II-2 sets requirements for the number, location and equipment of fireman’s outfits carried aboard, and correctly labelled lockers are part of demonstrating that this equipment is genuinely maintained and ready during Port State Control inspections and class surveys. Fitting SKU FS0251 keeps your safety equipment signage matched to the fire control plan surveyors will reference.
Fix this sign directly above or beside the safety locker door, using the pre-drilled fixing holes for a permanent mechanical fixing or the self-adhesive backing on smooth painted surfaces. In alleyways and machinery space accesses exposed to traffic, vibration and cleaning chemicals, a screw or rivet fixing will outperform adhesive over the vessel’s operating life, and the sign should remain visible even when nearby equipment or stores are shifted. Check the sign periodically during routine fire equipment rounds to confirm it remains legible and the locker beneath it is unobstructed.
Order the FS0251 Safety Locker sign to keep your vessel’s protective firefighting equipment clearly identified before your next drill or inspection. Safety Sign Hub stocks the complete IMO fire control symbol range and ships marine-grade signage across Australia and to vessels in port.
Browse the full Fire Fighting Signs range for every fire control plan symbol your vessel needs, or see our Hazard Signs for ISO 7010 warning pictograms to complete your safety signage programme.