| Product CodeFS0005 | IMPA Code33.6103 | ISSA Code47.561.03 |
Fire Locker Sign – IMO marine safety sign.
Other sizes on request. Film specifications on the Specifications tab.
$22.00 inc GST
| Product CodeFS0005 | IMPA Code33.6103 | ISSA Code47.561.03 |
Fire Locker Sign – IMO marine safety sign.
Other sizes on request. Film specifications on the Specifications tab.
| Product | |
| Product code | FS0005 |
|---|---|
| IMPA code | 33.6103 |
| ISSA code | 47.561.03 |
| Sizes | 150 × 150 mm, 300 × 300 mm · other sizes on request |
| Film options | |
| Self-Adhesive Vinyl (Non-Glow) | Polymeric PVC with UV laminate. No glow. Up to 5 yrs outdoor. |
| General Purpose Glow Vinyl | 200 µm photoluminescent vinyl, approx. 8 hr afterglow. Not certified – not for marine or escape-route use. Up to 7 yrs outdoor. |
| Marine Glow Vinyl (Class C) | Printed on DNV MED-certified film. ISO 15370:2021. ≥140 / ≥20 mcd/m² at 10 / 60 min, 28+ hr afterglow. Flame-retardant. Up to 5 yrs outdoor. |
| Marine High Intensity Glow Vinyl (Class D) | Printed on DNV MED-certified film. ISO 15370:2021. ≥260 / ≥35 mcd/m² at 10 / 60 min, 50+ hr afterglow. Nearly 2× Class C – escape routes, LLL, low-light areas. Flame-retardant. Up to 5 yrs outdoor. |
| Substrates | |
| Self-adhesive | Peel-and-stick onto flat, clean, non-porous surfaces – bulkheads, doors, cabinets, painted steel. Default. |
| Rigid PVC | Light, economical panel for interior mounting. Screw or adhesive fix. |
| Polycarbonate | Impact-resistant, UV-stable – exterior and high-traffic locations. |
| Aluminium | Corrosion-resistant, long-life exterior and deck use. |
| Steel | Heavy-duty industrial mounting; magnet-compatible. |
Full film data sheets and care instructions on our Materials page.
This IMO fire control sign identifies a fire locker — a dedicated cabinet or compartment on board where fire-fighting equipment such as hoses, nozzles, spanners, and breathing apparatus is stowed ready for immediate use. The pictogram shows a fireman’s helmet against a stylised flame, the standard symbol crew are trained to recognise at a glance as marking a source of fire-fighting gear rather than a fire hazard itself.
Fire lockers are positioned throughout a vessel wherever fire-fighting equipment needs to be readily accessible: alongside fire hose reel stations, near machinery space entrances, along accommodation escape routes, and on open decks close to cargo or bunkering operations. This sign is mounted directly on the locker door or the bulkhead immediately above it, so crew responding to an alarm can locate the nearest cache of equipment without hesitation, even when visibility is reduced by smoke.
Because a fire locker’s contents are only useful if crew can find the locker itself under pressure, the sign must stay fully visible at all times. It should never be obscured by stowed cargo, coiled lines, or maintenance equipment left in front of the cabinet, and paintwork carried out nearby should always mask around the sign rather than paint over it.

During weekly and monthly fire equipment inspections, crew check that each fire locker is correctly signed, that the door opens freely, and that the equipment inside matches what is recorded on the fire control plan for that location. Any locker found unsigned, mislabelled, or with equipment missing should be corrected and logged immediately, since a fire locker crew cannot locate in an emergency provides no benefit at all.
This sign is also checked during SOLAS fire safety surveys, where the surveyor confirms that every fire locker shown on the vessel’s approved fire control plan is present, correctly stocked, and permanently marked with the appropriate pictogram. Consistent, legible fire locker signage across the vessel is one of the clearer indicators a surveyor uses to judge whether a crew’s fire safety practices are maintained day to day, not just prepared for inspection.
New crew and cadets are walked past every fire locker during familiarisation rounds, since knowing exactly where spare hoses, nozzles, and breathing apparatus are stowed before an incident occurs can materially shorten the time it takes to mount an effective first response. Fire lockers are commonly ordered alongside other fire station equipment, such as the emergency phone sign used to raise the alarm and coordinate a response from the same general area.
Fire locker signage should also be reviewed whenever a vessel’s fire control plan is updated following equipment relocation or a refit, so that the physical signage on board always matches the plan crew and shore-side responders rely on in an emergency. Ship chandlers and safety equipment suppliers typically stock a matching fire locker sign for every locker size in use across a fleet, making it straightforward to keep signage consistent when equipment is relocated or additional lockers are fitted during a refit.
Technical specifications:
SKU: FS0005
IMPA: 33.6103
ISSA: 47.561.03
Compliant: IMO Resolution A.1116(30)
Supplied ready to apply directly to a clean, dry surface on or above the fire locker door. Available in the standard sizes shown above to suit lockers and cabinets of different scale throughout the vessel.
This sign is produced to IMO fire control symbol specifications for consistent recognition across international fleets. Need a different size? Contact us for a quote.
Fire Locker Sign
Reviews